Skip to main content

RHM 60 - 4" ANSI 150# Flanged Standard Sensor w/ Outputs Only

Request a Quote at 888-722-FLOW (3569)

Sensor #:
M#60S-N1M1-PFONN-A27J9-NNNNNNN-AN-NN
Transmitter #:
E49-C1D1-SOS1-NNNN-E2-NNN

The RHM 60 is an all-purpose meter suitable for liquid processing plants. A wide application flow range capability allows for commonality of installation across numerous lines – a real benefit to owners and operators.

Basic Information

Mass Flow Range: 66 - 6614 lb/min (30 - 3000 kg/min)
Accuracy: 0.2% of Flow Rate
Connection Size: 4"
Connection Type: ANSI 150# Flanged
Pressure Tolerance: Flange Rule
Fluid Temperature Tolerance (@100°F Ambient): -4°F to +194°F (-20°C to +90°C)

Specifications

Volumetric Flow Range (Volume Flow Range for Water at Room Temp/1500 PSI**): 7.91 - 790.9 GPM
Nominal Flow Range: Mass: 5512 lb, Volume: 659.1 GPM
Sensor Type: Parallel / Dual Path Manifold w/ Integral Transmitter, Sealless
Sensor Test: All sensors are hydro-tested, calibrated, and supplied with a traceable calibration certificate.

Electronics

Power Supply: 12 to 24 VDC (+/- 10%)
Functions: Mass Flow w/ Normalized Density, Volume
Outputs: 1x 4-20mA, 2x Pulse, 1x RS485 (Modbus)
Display Type: None, Outputs Only
Conduit Entries: 1/2" NPT

Wetted Materials

Manifold: SS 316 L
Flow Tubes: SS 316Ti (HP)
Seals: None, Sealless
Connections: SS 316 Ti

Approvals/Ratings

Enclosure Ratings: IP66 / NEMA 4
Pressure: PED 2014/68/EU Article 4, Section 3 (SEP)
Hazardous Area: Available w/ Lead Time
Custody Transfer: Available w/ Lead Time
Marine: Available w/ Lead Time